Disinfection and Microbiological Control Protocol for Street Cleaning Vehicles Using Reclaimed Water to Prevent Legionella spp. and Other Microbial Indicators
e202611103
DOI:
https://doi.org/10.67113/resp.v100i1.1002Keywords:
Legionella, Reclaimed water, Street cleaning, Disinfection, Aerosols, Public HealthAbstract
BACKGROUND // The use of reclaimed water in urban street-cleaning vehicles may involve microbiological risks associated with the proliferation of Legionella spp. and aerosol generation. The aim of this study was to establish a cleaning and disinfection protocol for water tanks to prevent these risks.
METHODS // A twelve-month monitoring study was conducted on five 2.5 m3 water tank vehicles equipped with 200-bar aerosolisation systems and supplied with reclaimed water. A monthly cleaning and disinfection protocol using sodium hypochlorite was implemented, with monitoring of free chlorine concentration and pH. Physicochemical and microbiological parameters were analysed in the incoming water, tanks and spray nozzles using standardised methods.
RESULTS // The physicochemical parameters of the incoming water remained within the established parametric values. Microbiological analyses performed fifteen days after treatment showed Legionella spp. concentrations below 100 CFU/L, intestinal nematodes below 1 egg/10 L, and no detection of Escherichia coli throughout the monitoring period. The treatment used a mean free hypochlorous acid concentration of 5.20±0.55 mg/L for two hours.
Downloads
References
1. Cunha BA, Burillo A, Bouza E. (2016). Legionnaires’ disease. The Lancet, 387(10016), 376-385. https://doi.org/10.1016/S0140-6736(15)60078-2
2. Ministerio de la Presidencia. (2003). Real Decreto 865/2003, de 4 de julio, por el que se establecen los criterios higiénico-sanitarios para la prevención y control de la legionelosis (BOE núm. 171, de 18 de julio de 2003). Boletín Oficial del Estado. https://www.boe.es/eli/es/rd/2003/07/04/865
3. Ortega Crespo MI. (2007). ’Guía Técnica para la Prevención y Control de la Legionelosis’: visitas en la web del Ministerio de Sanidad a la Guía Técnica. Revista De Salud Ambiental, 7(2), 181-184. Recuperado a partir de https://ojs.diffundit.com/index.php/rsa/article/view/262
4. Ministerio de la Presidencia, Justicia y Relaciones con las Cortes. (2024). Real Decreto 1085/2024, de 22 de octubre, por el que se aprueba el Reglamento de reutilización del agua y se modifican diversos reales decretos que regulan la gestión del agua (BOE núm. 256, de 23 de octubre de 2024). Boletín Oficial del Estado. https://www.boe.es/eli/es/rd/2024/10/22/1085
5. Pérez Jiménez D, Diago Garrido Y, Corona Miranda B, Espinosa Díaz R, González Pérez JE. (2011). Enfoque actual de la salud ambiental. Revista Cubana de Higiene y Epidemiología, 49(1), 84-92. http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S1561-30032011000100010
6. Rock C, Gerba CP, Pepper IL. (2015). Recycled Water Treatment and Reuse. Environmental Microbiology (3ª ed., pp. 623-632). Academic Press. https://doi.org/10.1016/B978-0-12-394626-3.00027-2
7. Jjemba PK, Weinrich LA, Cheng W, Giraldo E, LeChevallier MW. (2010). Regrowth of potential opportunistic pathogens and algae in reclaimed-water distribution systems. Applied and Environmental Microbiology, 76(13), 4169-4178. https://doi.org/10.1128/AEM.03147-09
8. Riveros M, Ochoa TJ. Enteropatógenos de importancia en salud pública. Rev Peru Med Exp Salud Publica. 2015;32(1):157-164.
9. Peinador M, Quirós J. (2000). Nematodos en las plantas de tratamiento de agua para consumo humano en Costa Rica. Revista Costarricense de Salud Pública, 9(17), 33-44. Accedido November 28, 2024, desde: http://www.scielo.sa.cr/scielo.php?script=sci_arttext&pid=S1409-14292000000200006&lng=en&tlng=es.
10. Valero N, De Simón M, Gallés P, Izquierdo N, Arimon J, González R, Manzanares-Laya S, Avellanes I, Gómez A. (2017). Street cleaning trucks as potential sources of Legionella pneumophila. Emerging Infectious Diseases, 23(11), 1880-1882. https://doi.org/10.3201/eid2311.161390
11. España. Ministerio de la Presidencia. (1997). Real Decreto 664/1997, de 12 de mayo, sobre la protección de los trabajadores contra los riesgos relacionados con la exposición a agentes biológicos durante el trabajo. Boletín Oficial del Estado, núm. 124, de 24 de mayo de 1997. https://www.boe.es/eli/es/rd/1997/05/12/664/con
12. World Health Organization. (2013). Technical notes on drinking-water, sanitation and hygiene in emergencies: Note 3. Cleaning and disinfecting water storage tanks and tankers. World Health Organization. https://www.who.int/teams/environment-climate-change-and-health/water-sanitation-and-health/environmental-health-in-emergencies
13. Naciones Unidas. (2015). Transformar nuestro mundo: la Agenda 2030 para el Desarrollo Sostenible (Resolución A/RES/70/1). https://sdgs.un.org/2030agenda
14. Hamilton KA, Hamilton MT, Johnson W, Jjemba P, Bukhari Z, LeChevallier M, Haas CN. (2018). Health risks from exposure to Legionella in reclaimed water aerosols: Toilet flushing, spray irrigation, and cooling towers. Water Research, 134, 261-279. https://doi.org/10.1016/j.watres.2017.12.022
15. Ministerio de Sanidad. (2022). Real Decreto 487/2022, de 21 de junio, por el que se establecen los requisitos sanitarios para la prevención y el control de la legionelosis (BOE núm. 148, de 22 de junio de 2022). Boletín Oficial del Estado. https://www.boe.es/eli/es/rd/2022/06/21/487/con
16. Asociación Española de Normalización. (2017). UNE-EN ISO 11731:2017. Calidad del agua. Recuento de Legionella. UNE.
17. Asociación Española de Normalización. (2006). UNE 872:2006. Calidad del agua. Determinación de sólidos en suspensión. UNE.
18. International Organization for Standardization. (2016). ISO 7027-1:2016. Water quality-Determination of turbidity-Part 1: Quantitative methods. ISO.
19. Bailenger J. (1979). Mechanisms of parasitological concentration in coprology and their practical consequences. Journal of the American Medical Technology, 41(2), 65-71.
20. Asociación Española de Normalización. (2014). UNE-EN ISO 9308-2:2014. Calidad del agua. Recuento de Escherichia coli y bacterias coliformes. Parte 2: Método del número más probable. UNE.
21. Whiley H, Bentham R, Brown MH, Boehm AB. (2017). Legionella persistence in manufactured water systems: Past, present and future. Current Environmental Health Reports, 4(2), 256-266. https://doi.org/10.3389/fmicb.2017.01330
22. Cunha BA, Burillo A, Bouza E. (2016). Legionnaires’ disease. The Lancet, 387(10016), 376-385. https://doi.org/10.1016/S0140-6736(15)60078-2
Downloads
Published
How to Cite
Issue
Section
Categories
- Open access
- Epidemic outbreak
- Madrid
- Environmental pollution
- QA
- Education for health
- Effectiveness
- Efficiency
- Respiratory system diseases
- Emerging infectious diseases
- Infectious and parasitic diseases
- Occupational diseases
- Epidemiology
- Spain
- Case-control studies
- Assessment
- Economic evaluation
- Risk assessment
- Risk factor's
- History of Public Health
- Health indicator
- Environment
- World Health Organization
- Paramerican Health Organization
- Public health policies
- Legal responsability
- Occupational hazards
- School health
- Zoonosis
- Bacteria
- Chemical contamination
License
Copyright (c) 2026 Borja Garrido Arias

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Usted es libre de:
Compartir — copiar y redistribuir el material en cualquier medio o formato.
La licenciante no puede revocar estas libertades en tanto usted siga los términos de la licencia.
Bajo los siguientes términos:
Atribución — Usted debe dar crédito de manera adecuada , brindar un enlace a la licencia, e indicar si se han realizado cambios. Puede hacerlo en cualquier forma razonable, pero no de forma tal que sugiera que usted o su uso tienen el apoyo de la licenciante.
NoComercial — Usted no puede hacer uso del material con propósitos comerciales.
SinDerivadas — Si remezcla, transforma o crea a partir del material, no podrá distribuir el material modificado.
No hay restricciones adicionales — No puede aplicar términos legales ni medidas tecnológicas que restrinjan legalmente a otras a hacer cualquier uso permitido por la licencia.
Avisos:
No tiene que cumplir con la licencia para elementos del material en el dominio público o cuando su uso esté permitido por una excepción o limitación aplicable.
No se dan garantías. La licencia podría no darle todos los permisos que necesita para el uso que tenga previsto. Por ejemplo, otros derechos como publicidad, privacidad, o derechos morales pueden limitar la forma en que utilice el material.







![¿Cómo evaluar para la RESP? [PARA REVISORES]](https://ojs.sanidad.gob.es/public/site/images/rmartinb/pastilla-revisores-0eaa113abcbc4fc554c7c6c7840ca4c6.jpg)
![¿Cómo recibir avisos sobre nuevos artículos de la RESP? [PARA LECTORES]](https://ojs.sanidad.gob.es/public/site/images/rmartinb/pastilla-lectores-aa689338e95aab07df45b4b0d583188f.jpg)